Abstract

This paper presents a novel virtual instrument for PQ assessment, based in higher-order statistics. It implements a new power-quality index, which is thought to trigger the measurement procedure when an electrical fault comes about. The user interfaces include not only the online variance charts but also the skewness and kurtosis graphs, along with hybrid representations of variance versus higher-order statistics. Designed on the basis of 85 signals recorded, 50 Hz real-time with different disturbances. The instrument validates the PQ procedure during online sessions. The new monitoring strategy activates the analysis of the signal once the PQ index overpassed a predefined threshold. Results show that voltage sags and transients are classified within different clusters, with low uncertainty, using different types of graphs. This flexibility may allow the operator to reduce the subjectivities during the online monitoring session with an optimal computational solution.

Published in: Renewable Energy & Power Quality Journal (RE&PQJ, Nº. 15)
Pages: 43-48 Date of Publication: 2017/04/25
ISSN: 2172-038X Date of Current Version:
REF: 212-17 Issue Date: April 2017
DOI:10.24084/repqj15.212 Publisher: EA4EPQ

Authors and affiliations

Olivia Florencias-Oliveros, Agustín Agüera-Pérez, Juan-José González-de-la-Rosa, José-Carlos Palomares-Salas, José-María Sierra-Fernández
Research Group PAIDI-TIC-168, Computational Instrumentation and Industrial Electronics (ICEI), Spain
Department of Automation Engineering, Electronics, Architecture and Computer Networks. Polytechnic School of Algeciras, University of Cadiz

Key word

Power quality index, virtual instrument, real-time monitoring, higher-order statistics.

References

[1] M. H. J. Bollen, S. Bahramirad, and A. Khodaei, gIs there a place for power quality in the smart grid?,h Proc. Int. Conf. Harmon. Qual. Power, ICHQP, pp. 713.717, 2014.
[2] M. Farhoodnea, A. Mohamed, H. Shareef, and H. Zayandehroodi, gPower Quality Analysis of Grid-Connected Photovoltaic Systems in Distribution Networks,h Przegl.d Elektrotechniczny, no. 2, pp. 208.213, 2013.
[3] C. Muscas, gPower quality monitoring in modern electric distribution systems,h IEEE Instrum. Meas. Mag., vol. 13, no. 5, pp. 19.27, 2010.
[4] I. Monedero, C. Leon, and J. Ropero, gClassification of Electrical Disturbances in Real Time Using Nueral Networks,h IEEE Trans. Power Deliv., pp. 1.9, 2007.
[5] J. Jose, G. De, A. Aguera-Perez, J. C. Palomares-Salas, J. M. Sierra-Fernandez, and A. Moreno-Munoz, gA novel virtual instrument for power quality surveillance based in higher-order statistics and case-based reasoning,h Mesurement, vol. 45, pp. 1824.1835, 2012.
[6] S. S. S. R. Depuru, L. Wang, and V. Devabhaktuni, gSmart meters for power grid: Challenges, issues, advantages and status,h Renew. Sustain. Energy Rev., vol. 15, no. 6, pp. 2736.2742, 2011.
[7] M. H. J. Bollen, I. Y. H. Gu, P. G. V Axelberg, and E. Styvaktakis, gClassification of underlying causes of power quality disturbances: Deterministic versus statistical methods,h EURASIP J. Adv. Signal Process., vol. 2007, 2007.
[8] L. Angrisani, P. Daponte, and M. D'Apuzzo, gWavelet network-based detection and classification of transients,h IEEE Trans. Instrum. Meas., vol. 50, no. 5, pp. 1425.1435, 2001.
[9] J. C. As, J. Jose, G. De, J. M. Sierra-Fernandez, D. Ayora-Sedeno, and A. Moreno-Munoz, gCharacterization of electrical sags and swells using higher-order statistical estimators q,h Measurement, vol. 44, pp. 1453.1460, 2011.
[10] M. V. Ribeiro, C. A. G. Marques, C. A. Duque, A. S. Cerqueira, and J. L. R. Pereira, gDetection of disturbances in voltage signals for power quality analysis using HOS,h EURASIP J. Adv. Signal Process., vol. 2007, 2007.
[11] J. J. G. De La Rosa, A. Moreno, and C. G. Puntonet, gA practical review on higher-order statistics interpretation. Application to electrical transients characterization,h ISPA 2007 - Proc. 5th Int. Symp. Image Signal Process. Anal., pp. 224.229, 2007.
[12] O. . N. Gerek and D. G. Ece, gPower-quality event analysis using higher order cumulants and quadratic classifiers,h IEEE Trans. Power Deliv., vol. 21, no. 2, pp. 883.889, 2006.
[13] K. Zhou, C. Fu, and S. Yang, gBig data driven smart energy management: From big data to big insights,h Renew. Sustain. Energy Rev., vol. 56, pp. 215.225, 2016.
[14] 1159-1995 IEEE Std, IEEE Recommended Practice for Monitoring Electric Power Quality. 1995.
[15] UNE-EN 50160: gVoltage characteristics of electricity supplied by public distribution networksh, 2008, [Online] Available: http://www.aenor.es/.
[16] UNE-EN 61000-4-30: gElectromagnetic compatibility (EMC). Part 4-30: Testing and measurement techniques . Power quality measurement methodsh, 2009.