Analysis of the Power Quality in Six-phase Induction
Motor Drives with Arbitrary Winding Spatial Shifting
J.J. Aciego, M.J. Duran, I. Gonzalez-Prieto
and F. Barrero
2017/04/25
|

Abstrac
Multiphase machines are becoming an alternative
to the three-phase standard in high power applications with high reliability
requirements. Due to the capability to inherit off-the-shelf three-phase
technology, the most popular choice at industry is the use of multiple
three-phase windings. The disposition of the different sets of three-phase
winding is however varied. In the specific case of six-phase machine,
a spatial shifting among the three-phase windings of 0º, 30º
and 60º has been used in dual-three-phase, asymmetrical and symmetrical
machines, respectively. This spatial displacement has an impact on the
power quality of the currents that supply the machine since the same magnetomotive
force (MMF) in the airgap can be generated with different harmonic cancellation
between phases. This work considers an arbitrary spatial shifting of the
three-phase windings in order to explore its impact on the power quality
from the machine-side. Extensive simulation results compared the different
types of six-phase machine and some conclusions are extracted about the
advantages of each choice.
| Published in: Renewable Energy
& Power Quality Journal (RE&PQJ, Nº. 15) |
| Pages: 479-484 |
Date of Publication: 2017/04/25 |
| ISSN: 2172-038X |
Date of Current Version: |
| REF: 359-17 |
Issue Date: April 2017 |
| DOI:10.24084/repqj15.359 |
Publisher: EA4EPQ |
Authors and affiliations
J.J. Aciego(1), M.J. Duran(1), I. Gonzalez-Prieto(1)
and F. Barrero(2)
1. Department of Electrical Engineering. E.T.S.I.I., University of Málaga.
Spain
2. Department of Electronic Engineering. University pf Seville. Spain
Key word
Six-phase drives, induction machines, power quality.
References
[1] E. Levi, R. Bojoi, F. Profumo, H.A. Toliyat and S.
Williamson, Multiphase induction motor drives - A technology status
review, IET Electric Power Applications, vol. 1, no. 4, pp. 489-516,
2007.
[2] E. Levi, F. Barrero and M.J. Duran, Multiphase machines and
drives Revisited, IEEE Trans. Ind. Electron., vol 63, no.
1, pp. 429-432, 2016.
[3] E. Levi, Advances in converter control and innovative exploitation
of additional degrees of freedom for multiphase machines, IEEE Trans.
Ind. Electron., vol 63, no. 1, pp. 433-448, 2016.
[4] F. Barrero and M.J. Duran, Recent advances in the design, modeling
and control of multiphase machines Part 1, IEEE Trans. Ind.
Electron., vol 63, no. 1, pp. 449-458, 2016. https://doi.org/10.24084/repqj15.359
483 RE&PQJ, Vol.1, No.15, April 2017
[5] M.J. Duran and F. Barrero, Recent advances in the design, modeling
and control of multiphase machines Part 2, IEEE Trans. Ind.
Electron., vol 63, no. 1, pp. 459-468, 2016.
[6] H.S. Che, M.J. Duran, E. Levi, M. Jones, W.P. Hew and N.A. Rahim,
Post-fault operation of an asymmetrical six-phase induction machine
with single and two isolated neutral points, IEEE Trans. on Power
Electronics, vol. 29, no. 10, pp. 5406-5416, 2014.
[7] I. Gonzalez-Prieto, M.J. Duran, F. Barrero, M. Bermudez and H. Guzman,
Impact of post-fault flux adaptation on six-phase induction motor
drives with parallel converters, IEEE Trans. on Power Electronics,
early access, DOI: 10.1109/TPEL.2016. 2533719, 2016.
[8] H. Guzman, M.J. Duran, F. Barrero, B. Bogado, I. Gonzalez-Prieto and
M.R. Arahal, Comparative study of predictive and resonant controllers
in fault-tolerant five-phase induction motor drives, IEEE Trans.
Ind. Electron., vol. 63, no. 1, pp. 606-617, 2016.
[9] H.S. Che, E. Levi, M. Jones, M.J. Duran, W.P. Hew, and N.A. Rahim,
Operation of a six-phase induction machine using series-connected
machine-side converters, IEEE Trans. Ind. Electron., vol. 61, no.
1, pp. 164-176, 2014.
[10] I. Subotic, N. Bodo, E. Levi and M. Jones, Onboard integrated
battery charger for EVs using an asymmetrical nine-Phase Machine,
IEEE Trans. Ind. Electron., vol 62, no. 5, pp. 3285-3295, 2015.
[11] M.J. Duran, I. Gonzalez-Prieto, F. Barrero, M. Mengoni, L. Zarri
and E. Levi, A simple braking method for six-phase induction motor
drives with diode front-end rectifier, Industrial Electronics Society,
IECON 2015 41st Annual Conference of the IEEE, 9-12 Nov. 2015.
[12] S. Dwari and L. Parsa, An optimal control technique for multiphase
PM machines under open-circuit faults, IEEE Trans. Ind. Electron.,
vol. 55, no. 5, 2008

|
|