Comparative Analysis of Single-Phase Grid-Tied
PV Systems with Single and Double Power Conversion Stages
L. P. Sampaio, S. A. O. Silva and M. Miranda
2017/04/25
|

Abstrac
This paper presents a comparative analysis
of two single-phase grid-tied photovoltaic (PV) systems. The first is
deployed employing a single-stage power conversion, while the second a
double-stage power conversion is used. In the single-stage PV system topology
the impedance source inverter (ZSI) is used to perform the maximum power
point tracking (MPPT), as well as the control of the active current injected
into the grid. On the other hand, in the double-stage PV system a dc-dc
boost converter (BC) performs the MPPT, whereas a voltage source inverter
(VSI) controls the amount of energy injected into the grid. In both aforementioned
PV systems, Perturb and Observe (P&O) based algorithm is employed
to perform the MPPT. The comparative analysis takes into account the following
aspects: i. converter efficiency; ii MPPT efficiency; iii total harmonic
distortion of the grid-tied inverter current; and iv. number of electrical
and electronic devices needed to implement the PV systems. Furthermore,
the ZSI and BC+VSI modelling and the procedures used to design the controller
gains are also presented. Finally, by means of computational simulations,
the performance and functionality of the ZSI and BC+VSI PV systems are
evaluated.
| Published in: Renewable Energy
& Power Quality Journal (RE&PQJ, Nº. 15) |
| Pages: 534-539 |
Date of Publication: 2017/04/25 |
| ISSN: 2172-038X |
Date of Current Version: |
|
REF: 385-17
|
Issue Date: April 2017 |
| DOI:10.24084/repqj15.385 |
Publisher: EA4EPQ |
Authors and affiliations
L. P. Sampaio, S. A. O. Silva and M. Miranda
Department of Electrical Engineering. Federal University of Technology
UTFPR-CP, Cornélio Procópio PR - Brazil
Key word
Impedance Source Inverter, Voltage Source Inverter, Photovoltaic
Systems, Perturb and Observe.
References
[1] C. S. da Silva, F. R. Motta and F. L. Tofoli, "Two-Stage
Single-Phase Grid-Connected Photovoltaic System with Reduced Complexity",
International Journal Electronics. vol. 98, nº 6, pp. 753-767, June
2011.
[2] S. A. O. Silva, L. P. Sampaio, F. M. Oliveira and F. R. Durand, "Feed-forward
DC-bus Control Loop Applied to a Single-Phase Grid-Connected PV System
Operating with PSO-based MPPT Technique and Active Power-Line Conditioning",
IET Renewable Energy [online], http://digital-library.theiet.org/content/journals/10.1049/ie
t-rpg.2016.0120, accessed 12 December 2016.
[3] S. Jain and V. Agarwal, "A Single-Stage Grid Connected Inverter
Topology for Solar PV Systems with Maximum Power Point Tracking",
IEEE Transactions on Power Electronics, vol. 22, nº 5, pp. 1928-1940,
Sep. 2007.
[4] Y. Li, P. Li, Y. Chen and D. Zhang, "Single-Stage Three- Phase
Current-Source Inverter for Photovoltaic Grid- Connected System",
in Proc. of EPE, 2014, pp. 1-9.
[5] O. Ellabban, H. Abu-Rub, "Z-Source Inverter: Topology Improvements
Review", IEEE Industrial Electronics Magazine, vol. 10, no. 1, pp.
6-24, 2016.
[6] M. Adamowicz, R. Strzelecki, F. Z. Peng, J. Guzinski and H. A. Rub,
"New type LCCT-Z-source inverters", in Proc. of EPE, 2011, pp.
1-10.
[7] M. Shen, A. Joseph, J. Wang, F. Z. Peng and D. J. Adams, "Comparison
of Traditional Inverters and Z-Source
https://doi.org/10.24084/repqj15.385
538 RE&PQJ, Vol.1, No.15, April 2017
Inverter for Fuel Cell Vehicles", IEEE Transactions on Power Electronics,
vol. 22, n° 4, pp. 1453-1463, July 2007.
[8] F. Z. Peng, M. Shen and Z. Qian, "Maximum Boost Control of the
Z-Source Inverter", IEEE Transactions on Power Electronics, vol.
20, n° 4, pp. 833-838, July 2005.
[9] C. J. Gajanayake, M. Vilathgamuwa and P. C. Loh, "Development
of a Comprehensive Model and a Multiloop Controller for Z-Source Inverter
DG Systems", IEEE Transactions on Industrial Electronics, vol. 54,
n° 4, pp. 2352-3259, Aug. 2007.
[10] N. Femia, G. Petrone, G. Spagnuolo and M. Vitelli, "A Technique
for Improving P&O MPPT Performance of Double-Stage Grid-Connected
Photovoltaic Systems", IEEE Transactions on Industrial Electronics,
vol. 56, n° 11, pp. 4473-4482, Aug. 2009.
[11] V. D. Bacon, S. A. O. Silva, L. B. G. Campanhol and B. A. Angélico,
"Analysis and Performance Evaluation of a Single-Phase Phase-Locked
Loop Algorithm Using a Non-Autonomous Adaptive Filter", IET Power
Electronics, vol. 7, nº 8, pp. 2081-2092, 2014.
[12] B. A. Angélico, L. B. G. Campanhol and S. A. O. Silva, "Proportional-Integral/Proportional-Integral-Derivative
Tuning Procedure of a Single-Phase Shunt Active Power Filter Using Bode
Diagram", IET Power Electronics, vol. 7, nº 10, pp. 2647-2659,
2014.
[13] M. A. G. Brito, L. P. Sampaio, L. Galotto Jr. and C. A. Canesin,
"Evaluation of the main MPPT techniques for photovoltaic applications",
IEEE Transactions on Industrial Electronics, vol. 60, nº 3, pp. 1156-1167,
2013.
[14] IEEE Std. 929-2000: "IEEE recommended practice for utility interface
of photovoltaic (PV) systems", 2000.

|
|