Testing and analysis of a fuel cell based stand-alone
power system
for residential use
J. García-Villalobos, I. Zamora, J.
I. San Martín, F. J. Asensio, I. Junquera
2017/04/25
|

Abstract
Nowadays, there are residential buildings
which cannot be connected to a distribution network, due to the lack of
electric infrastructure. Also, there are other electric applications where
it is necessary to have a back-up system, i.e. hospitals, hotels, etc.
Additionally, there are users who just want to be off-grid. In all these
cases, a dedicated stand-alone generation system can provide a valuable
service.
In this context, this paper is focused on testing and analysis of a real
small stand-alone generation system composed by two proton membrane exchange
fuel cells (PEMFC) and a micro wind generator (WG). The key feature of
this configuration is to be an on-site zero-emission system. Additionally,
quality of supply and energy efficiency of this microgrid in islanded
mode are analyzed. Furthermore, possible optimization methods and future
enlargements of the system are proposed, in order to improve the overall
efficiency of the proposed microgrid.
| Published in: Renewable Energy
& Power Quality Journal (RE&PQJ, Nº. 15) |
| Pages: 581-586 |
Date of Publication: 2017/04/25 |
| ISSN: 2172-038X |
Date of Current Version: |
|
REF: 400-17
|
Issue Date: April 2017 |
| DOI:10.24084/repqj15.400 |
Publisher: EA4EPQ |
Authors and affiliations
J. García-Villalobos(1), I. Zamora(1), J. I.
San Martín(2), F. J. Asensio(2), I. Junquera(1)
1. Department of Electrical Engineering University of the Basque Country
(UPV/EHU). Bilbao (Spain)
2. Department of Electrical Engineering University of the Basque Country
(UPV/EHU). Eibar (Spain)
Key word
Fuel cell, wind turbine, zero emissions, stand-alone,
off-grid, microgrid
References
[1] Off-Grid solar market trends report,
2016. [Online]. Available: http://www.energynet.co.uk/webfm_send/1690.
[Accessed: 03-Nov-2016].
[2] N. W. a. Lidula and a. D. Rajapakse, Microgrids research: A
review of experimental microgrids and test systems, Renew. Sustain.
Energy Rev., vol. 15, no. 1, pp. 186202, Jan. 2011.
[3] K. S. Lee, H. J. Lee, S. C. Sin, J. H. Kim, T. K. Lee, and C. Y. Won,
A stand-alone fuel cell generation system design, 2011 Int.
Conf. Electr. Mach. Syst. ICEMS 2011, 2011.
[4] H.-K. Chiang, B.-R. Lin, and Y.-A. Ou, Implementation of a stand-alone
fuel cell system for domestic applications, IEEE Reg. 10 Annu. Int.
Conf. Proceedings/TENCON, vol. D, pp. 187190, 2004.
[5] M. Bollen, Jin Zhong, and Yufeng Lin, Performance indices and
objectives for microgrids, in IET Conference Publications, 2009,
no. 607, pp. 607607.
[6] EN50160 - Voltage characteristics of electricity supplied by
public distribution systems.
[7] EN61000 part 2.2 - Compatibility levels for low frequency conducted
distubances and signalling in public low voltage (LV) power supply systems.
[8] J. I. San Martín, I. Zamora, F. J. Asensio, and J. García-Villalobos,
Control and management of a fuel cell microgrid. Energy efficiency
optimization, in International Conference on Renewable Energies
and Power Quality (ICREPQ13), 2013.

|
|