Drive the switched Reluctance Generator with mesh load Voltage Control

 

A.C. Assunção, A.W.F.V. Silveira, A.V.S. Fleury, D.A. Andrade, G.F. Cardoso J.R. Camacho and L.C. Gomes

 

2017/04/25

Abstract

This paper will present a voltage control strategy applied to the load for a triphasic variable reluctance generator 6x4. The developed strategy is based on the use of a proportional integral controller which generates a reference signal for a hysteresis controller, used to control the magnetization current. This signal is proportional to the difference between the voltage applied to the load and its reference value. This strategy uses an internal current control loop which has as its main advantage the possibility to aggregate protection routines to the control strategy. The strategy was implemented and tested through computational simulation and experimentally using the DSP platform.

Published in: Renewable Energy & Power Quality Journal (RE&PQJ, Nº. 15)
Pages: 713-718 Date of Publication: 2017/04/25
ISSN: 2172-038X Date of Current Version:

REF: 445-17

Issue Date: April 2017
DOI:10.24084/repqj15.445 Publisher: EA4EPQ

Authors and affiliations

A.C. Assunção¹, A.W.F.V. Silveira¹, A.V.S. Fleury², D.A. Andrade¹, G.F. Cardoso¹ J.R. Camacho¹ and L.C. Gomes¹.
1. Federal University of Uberlandia. Campus Santa Mônica – Minas Gerais, (Brazil)
2. Federal Institute of Education, Science and Technology of Goiás Campus Henrique Santillo – Goiás, (Brazil)

Key word

Switched reluctance generator, half-bridge converter, load voltage control.

References

[1] Borges, T. T. (2002). Motor a relutância chaveado com controle Fuzzy e detecção inditera de posição (Doctoral dissertation, Tese de Doutorado, UFU).
[2] Rahman, K. M., Fahimi, B., Suresh, G., Rajarathnam, A., V., & Ehsani, M. (2000). Advantages of switched reluctance motor aplications to EV and HEV: desing and control issues. Idustry Applications, IEEE Transactions on, 36(1), 111-121.
[3] Silveira, A. W. F. V., Andrade, D. A., Gomes, L. C., Bissochi Jr, C. A., & de Paula, H. (2010). Generated voltage control in a switched reluctance motor/ generator. Eletrônica de Potência, 15(3), 203-212.
[4] Fleury, A. V. S., Silva, F. S., Araújo, W. R. H., Andrade, D. A., & Silveira, A. W. F. V. (2008). Reduced switch count converter for switched reluctance generators. Eletrônica de Potência, 13(3).
[5] Coelho, A. (2011). Simulação, Projeto e Teste de um Gerador a Relutância Chaveado Trifásico 6 x 4 (Doctoral dissertation, Universidade de São Paulo).
[6] B. Bilgin, A. Rmadi, M. Krishnamurthy, “Desing Considerations for Switched Reluctance Machines With a Higher number of Rotor Poles”, IEEE Trans. On Industrial Electronics, vol. 59, no.10 pp. 3745-3756, 2012.
[7] Lopes Oliveira, E. S., Aguiar, M. L., &Nunes da Silva, I. (2015). Strategy to Control the Terminal Voltage of a SRG Based on the Excitation Voltage. Latin America Transactions, IEEE (Revista IEEE America Latina), 13(4), 975-981.