Abstract
The objective of this study was to build
a thermally efficient solar water heater. The receiver plate was constructed
from an air conditioner radiator, and consisted of an array of serpentine
tubes through which water was circulated. The presence of high density
corrugated fins attached to the tubes increased the absorption of incident
solar radiation. The flat plate collector was enclosed by double glazing
which admitted solar radiation and minimized convection heat transfer
losses to the environment. The shell of the collector was insulated to
reduce conduction losses. A numerical model of flat plate solar collector
thermal performance was developed and is likewise described in this paper.
The model predicted the useful heat transfer to the water using an energy
balance approach. An experimental program that was devised to verify the
accuracy of the thermal performance model. Under certain circumstances
close agreement was obtained between model predictions and experimental
measurements, making the performance model of the flat plate solar collector
a useful design tool.
| Published in: Renewable Energy
& Power Quality Journal (RE&PQJ, Nº. 16) |
| Pages: 33-38 |
Date of Publication: 2018/04/20 |
| ISSN: 2172-038X |
Date of Current Version:2018/03/23 |
| REF: 205-18 |
Issue Date: April 2018 |
| DOI:10.24084/repqj16.205 |
Publisher: EA4EPQ |
Authors and affiliations
Vikas Reddy Chittireddy1, Ahmed ElSawy2*, and Stephen
Idem3
2 M.S. In Mechanical Engineering Candidate and 2, 3 Professors and Faculty
Advisors
College of Engineering, Tennessee Technological University, Cookeville,
Tennessee 38505, USA
Key words
Solar water heater, flat plate collector, double glazing,
energy balance, Newton-Raphson method
References
[1] 1. Zelzouli, K., Guizani, A., Sebai, R. and Kerkeni,
C. (2012), "Solar Thermal Systems Performances versus Flat Plate
Solar Collectors Connected in Series," Engineering, Vol. 4, No. 12,
pp. 881-893. doi: 10.4236/eng.2012.412112.
2. Jouhari, M., Touhmeh, S. and Moukhayber, N. (2015), Manufacturing and
Thermal Performance Test of (Compound) Solar Collector in Damascus City.
Journal of Biomedical Science and Engineering, Vol. 8, pp. 370-379. doi:10.4236/jbise.2015.86035.
3. Ben Slama, R. (2012), "Experimentation of a Plane Solar Integrated
Collector Storage Water Heater," Energy and Power Engineering, Vol.
4, No. 2, pp. 67-76. doi: 10.4236/epe.2012.42010.
4. Ihaddadene, N., Ihaddadene, R., Mahdi, A. (2014), Effect of Glazing
Number on the Performance of a Solar Thermal Collector, International
Journal of Science and Research, Vol. 3, Issue 6, pp. 1199-1203.
5. Ihaddadene, N., Ihaddadene, R., Mahdi, A. (2014), Effect of Distance
between Double Glazing on the Performance of a Solar Thermal Collector,
International Conference on Renewable Energies and Power Quality (ICREPQ14)
Cordoba (Spain), pp. 302-306.
6. Al-Khaffajy, M. and Mossad, R. (2013), Optimization of the Heat
Exchanger in a Flat Plate Indirect Heating Integrated Collector Storage
Solar Water Heating System, Renewable Energy, volume 57, pp. 413-421.
7. Shukla, R., Sumathy, K., Erickson, P., and Gong, J. (2013), Recent
advances in the solar water heating systems: A review, Renewable
and Sustainable Energy Reviews, Vol. 19, pp. 173-190.
8. ASHRAE. 2013. ASHRAE Handbook Fundamentals, Chapter 4, Atlanta:
American Society of Heating, Refrigerating and Air-Conditioning Engineers,
Inc.
9. http://www.plexiglas.com/export/sites/plexiglas/.content/medias/downloads/sheet-docs/plexiglas-general-information-and-physical-properties.pdf.
10. https://www.wunderground.com/personal-weather-station/dashboard?ID=KTNCOOKE16#history.
11. Kalidasan, B. and Srinivas, T. (2014), Study on Effect of Number
of Transparent Covers and Refractive Index on Performance of Solar Water
Heater, Journal of Renewable Energy, Article ID 757618. doi:10.1155/2014/757618.

|
|