Comparative Analysis
of the 6/4 and 8/6 Switched Reluctance Generator in Different
Operating Conditions
M. A. A. Freitas, G. P. Viajante,
D. A. Andrade, E. N. Chaves, C.A. Queiroz, L. G. W. Silva, R.
V. R. Silva, R.T. Fidelis and J.L. Domingos
2018/04/20
|

Abstract
This paper presents a comparative study between
two Switched Reluctance Generators 6/4 and 8/6 both of 60kW. The main
features of the two machines and the mathematical modeling that considers
the magnetic saturation effect are established. A computational simulation
was performed in Matlab/Simulink environment and has allowed the machine
behavior under various operating conditions to be verified. This work
made it possible to evaluate: ripple voltage, phase voltage and current,
speed, torque, flux, power, losses and efficiency. The comparative results
between the two generators are presented and discussed.
| Published in: Renewable Energy
& Power Quality Journal (RE&PQJ, Nº. 16) |
| Pages: 487-492 |
Date of Publication: 2018/04/20 |
| ISSN: 2172-038X |
Date of Current Version:2018/03/23 |
| REF: 360-18 |
Issue Date: April 2018 |
| DOI:10.24084/repqj16.360 |
Publisher: EA4EPQ |
Authors and affiliations
M. A. A. Freitas1, G. P. Viajante1, D. A. Andrade2,
E. N. Chaves1, C.A. Queiroz1, L. G. W. Silva1, R. V. R. Silva1 , R.T.
Fidelis2 and J.L. Domingos1
1. Federal Institute of Education, Science and Technology of Goiás.
Energy Systems Research Center (Núcleo de Pesquisas em Sistemas
de Energia - NuPSE). Brasil.
2. Electric Drives Laboratory, Federal University of Uberlândia.
Campus Santa Mônica, Uberlândia-MG, Brasil.
Key words
Switched Reluctance Generator, Half Bridge Converter
References
[1] Y.Chang, C.M. Liaw, On the design of power
circuit and control scheme for switched reluctance generator, Transactions
on Power Electronics, vol. 23, no. 1, 2008.
[2] Y.C. Chang, C.M. Liaw. Establishment of a Switched-Reluctance
Generator-Based Common DC Microgrid System, IEEE Transactions on
Power Electronics, Vol. 26, No. 9, pp. 2512-2527, September 2011.
[3] D. A. Andrade, R. Krishnan, "Characterization of Switched Reluctance
Machines Using Fourier Series Approach", in Proc. 36th IEEE Ind.
Appl. Annu. Meeting, pp. 48-54, Sep. 2001.
[4] G.P.Viajante, et all, "Estratégia para Melhoria da Eficiência
da Conversão Eletromecânica de Energia do SRG", IEEE
Eletrônica de Potência, v. 16, N°4, p. 367-375, 2011.
[5] Bao, Y.J.; Cheng, K.W.E. Research on a novel switched reluctance
generator for wind power generation IEEE PESA, 2011.
[6] Sozer ,Y. and Torrey, D. A. Closed Loop Control of Excitation
Parameters for High Speed Switched-Reluctance Generators, IEEE Transactions
On Power Electronics, Vol. 19, No. 2, March 2004.
[7] Silveira, A. W. F. V., Andrade, D. A., Fleury, A., Gomes, L. C. Bissochi
C. A., de Paula, H. Generated Voltage Control In A Switched Reluctance
Motor/Generator Eletrônica de Potência, v. 15, n. 3,
p. 203-212, jun./ago. 2010.
[8] Chen, H., Jason J. G, Implementation of the Three-Phase Switched
Reluctance Machine System for Motors and Generators IEEE Transactions
On Mechatronics, Vol. 15, No. 3, June 2010.
[9] Fleury, A. V. S., Silva F. S., Araújo, W. R. H., Andrade ,D.A.,
Silveira ,A. W. F. V. Reduced switch count converter for switched
reluctance generators Eletrônica de Potência, Vol. 13,
no. 3, Agosto 2008.

|
|