Abstract
This paper analyzes the performance of desert
type photovoltaic 1.4 kWP grid connected plant. The system was installed
in College of Engineering, Sultan Qaboos University, Oman and was monitored
since April 2012. The experimental results show that the total measured
annual energy produced was 2217.6 kWh with average system efficiency of
15% for the first year. The average capacity factor for the system was
17%.
| Published in: Renewable Energy
& Power Quality Journal (RE&PQJ, Nº. 17) |
| Pages: 275-279 |
Date of Publication: 2019/07/15 |
| ISSN: 2172-038X |
Date of Current Version:2019/04/10 |
| REF: 286-19 |
Issue Date: July 2019 |
| DOI:10.24084/repqj17.286 |
Publisher: EA4EPQ |
Authors and affiliations
A. H. Al-Badi
Department of Electrical & Computer Engineering. College of Engineering,
Sultan Qaboos University
Key words
Desert type PV, PV performance, Oman
References
[1] Eke R, Demircan H. Performance analysis of a multi
crystalline Si photovoltaic module under Mugla climatic conditions in
Turkey. Energy Conversion and Management 2013;65:580-6.
[2] Adaramola MS. Techno-economic analysis of a 2.1 kW rooftop photovoltaic-grid-tied
system base on actual performance. Energy Convers Manag 2015;101:85-93.
[3] Mpholo M, Nchaba T, Monese M. Yield and performance analysis of the
first grid connected solar farm at Moshoeshoe I International Airport,
Lesotho. Renew Energy 2015;81:845-52.
[4] Kumar KA, Sundareswaran K, Venkateswaram PR. Performance study on
a grid connected 20 kWp solar photovoltaic installation in an industry
in Tiruchirappalli (India). Energy Sustain Dev 2014;23:294-304.
[5] Padmavathi K, Daniel SA. Performance analysis of a 3 MWp grid connected
solar photovoltaic power plant in India. Energy Sustain Dev 2013;17:615-25.
[6] L. Lima, L. Ferreira, F. Morais. Performance analysis of a grid connected
photovoltaic system in northeastern Brazil. Energy for Sustainable Development
37 (2017) 79-85
[7] L. Ayompe, A. Duffy, S. McCormack, M. Conlon. Measured performance
of a 1.72 kW rooftop grid connected photovoltaic system in Ireland. Energy
Conversion and Management 52 (2011) 816825
[8] A.H. Al-Badi, "Wind Power Potential in Oman ", International
Journal of Sustainable Energy Vol. 30, No. 2, April 2011, 110-118.
[9] S. Al-Yahyai, Y. Charabi, A. Al-Badi, and A. Gastli, "Ensemble
NWP Approach for Wind Energy Assessment," in
press, Renewable Energy.
[10]A.H. Al-Badi, A. Malik and A. Gastli, Sustainable Energy Usage
in Oman - Opportunities and Barriers Renewable and Sustainable Energy
Reviews, Vol.15, 2011, pp. 37803788. http://dx.doi.org/10.1016/j.rser.2011.06.007.
[11] A. Malik and A.H. Al-Badi," Economics of Wind Turbine as an
Energy Fuel Saver - A Case Study for Remote Application in Oman",
Energy 34 (2009) 1573-1578
[12] A. H. Al-Badi, "Hybrid (solar and wind) energy system for Al
Hallaniyat Island electrification", International Journal of
Sustainable Energy, Vol. 30, No. 4, August 2011, 212-222.
[13] A. Al-Badi and H. Bourdosen," Study and Design of Hybrid Diesel
-Wind Stand-Alone System for Remote Area in Oman", in press, International
Journal of Sustainable Energy.
[14] A.H. Al-Badi, M. AL-Toobi, S. AL-Harthy, Z. Al-Hosni, A. AL-Harthy,"
Hybrid Systems for Decentralized Power
Generation in Oman", in press, International Journal of Sustainable
Energy.
[15] A. H. Al-Badi, M. H. Al-Badi, A. M. Al-Lawati and A. S. Malik, "Economic
Perspective for PV Electricity in Oman",
Energy 36 (2011) 226-232.
[16] A. H. Al-Badi, Y. Charabi, A. Gastli and Y. Al-Shaili, Measurement
of Grid Solar PV System in Oman, International
Conference on Engineering and Technology (BICET 2014), Brunei, Nov. 1-3,
2014.
[17] Fuentes M, Nofuentes G, Aguilera J, Talavera DL, Castro M. Application
and validation of algebraic methods to predict the behaviour of crystalline
silicon PV modules in Mediterranean climates. Sol Energy 2007;81:1396408.
[18] M. Yaacob, H. Hizam, T. Khatib, M. Radzi, A comparative
study of three types of grid connected photovoltaic
systems based on actual performance, Energy Conversion and Management
78 (2014) 813
[19] D. Micheli, S. Alessandrini, R. Radu, I. Casula, Analysis of
the outdoor performance and efficiency of two grid
connected photovoltaic systems in northern Italy, Energy Conversion
and Management 80 (2014) 436445
[20] S. Wittkopf, S. Valliappan, L. Liu, K. Ang, S. Cheng Analytical
performance monitoring of a 142.5 kWp gridconnected
rooftop BIPV system in Singapore, Renewable Energy 47 (2012) 9-20
[21] S. Edalati, M. Ameri, M. Iranmanesh,Comparative performance
investigation of mono- and poly-crystalline silicon
photovoltaic modules for use in grid-connected photovoltaic systems in
dry climates, Applied Energy 160 (2015) 255265
[22] Kazem HA, Khatib T, Sopian K, Elmenreich W. Performance and feasibility
assessment of a 1.4 kW roof top
grid-connected photovoltaic power system under desertic weather conditions.
Energy Build 2014;82:1239.
[23] Pietruszko SM, Gradzki M. Performance of a grid connected small PV
system in Poland. Appl Energy 2003;74:17784.
[24] Sharma V, Chandel SS. Performance analysis of a 190 kWp grid interactive
solar photovoltaic power plant in India.
Energy 2013;55:47685.
[25] C. Sidi, M. Ndiaye, M. El Bah, A. Mbodji, A. Ndiaye, P. Ndiaye, Performance
analysis of the first large-scale (15
MWp) grid-connected photovoltaic plant in Mauritania, Energy Conversion
and Management 119 (2016) 411421
[26] Phinikarides A, Makrides G, Zinsser B, Schubert M, Georghiou GE.
Analysis of photovoltaic system performance
time series: seasonality and performance loss. Renew Energy 2015;77:5163.
[27] Sundaram S, Babu JSC. Performance evaluation and validation of 5
MWp grid connected solar photovoltaic plant in
South India. Energy Convers Manage 2015;100:42939.
[28] Al-Otaibi A, Al-Qattan A, Fairouz F, Al-Mulla A. Performance evaluation
of photovoltaic systems on Kuwaiti
schools rooftop. Energy Convers Manage 2015;95:1109.
[29] Kymakis, E., Kalykakis, S., Papazoglou, T.M., 2009. Performance analysis
of a grid connected photovoltaic park on the island of Crete. Energy Convers.
Manage. 50 (3), 433-438. [30] International Electrotechnical Commission.
IEC 61724, photovoltaic system performance monitoring guidelines for measurement,
data exchange and analysis. 1st ed. Geneva, IEC: International Electrotechnical
Commission; 1998.
[31] K. Attari, A. Elyaakoubi, A. Asselman. Performance analysis and investigation
of a grid-connected photovoltaic installation in Morocco. Energy Reports,
Volume 2, November 2016, Pages 261-266
[32] Padmavathi, K., Daniel, S., 2013. Performance analysis of a 3 MWp
grid connected solar photovoltaic power plant in India. Energy Sustainable
Dev. 17, 615-625
[33] Dragana, D., Tomislav, M., 2015. Performance analysis of A grid-connected
solar PV plant in Ni, republic of Serbia. Renew. Sustainable Energy
Rev. 44, 423-435.

|
|