Abstract Nowadays, three-phase inverters are playing an increasingly important role in various applications, such as drives, solar systems, energy storage systems. The commonly used PI current control method in the d-q coordinate system satisfies the requirements of most of the cases. However, in some specific applications, such as a grid-connected inverter for an energy storage system, the PI controller response time may not be sufficient to meet the criteria. This paper describes the application of the PCMC (Peak Current Mode Control) control technique, which is commonly used for DC-DC converters, and applies it to the case of three-phase two-level inverters. Advantages and disadvantages of PCMC compared to a conventional PI control solution are presented, and the performance of the two control techniques is compared for a grid connected energy storage inverter. Key words: Inverter, Grid, Peak Current Mode Control
References [1] K.-B. Park and S. Pettersson, “Peak current control for threephase inverter with lcl filter.” IEEE, 5 2021, pp. 104–107. [2] W. Choi, W. Lee, and B. Sarlioglu, “Effect of grid inductance on grid current quality of parallel grid-connected inverter [3] J. Munoz-Cruzado-Alba, J. Villegas-Nunez, J. A. Vite-Frias, [4] B. Baby and K. Mathew, “Modified peak and valley current mode control of single phase full bridge voltage source inverter using flux cancellation method.” IEEE, 12 2023, pp. 261–267. [5] D. G. Holmes, R. Davoodnezhad, and B. P. McGrath, “An improved three-phase variable-band hysteresis current regulator,” IEEE Transactions on Power Electronics, vol. 28, pp. 441–450, 1 2013. [6] N. Kobayashi, Y. Hayashi, S. Iyasu, and Y. Handa, “Digital peak current mode control method for the single-phase bidirectional dc-ac converter.” IEEE, 9 2021, pp. P.1–P.8. [7] ——, “Fast current control of the single-phase dc-ac converter using digital peak current mode control.” IEEE, 9 [8] M. Aime, G. Gateau, and T. Meynard, “Implementation of a peak current control algorithm within a field programmable [9] M. Ebrahimi and S. A. Khajehoddin, “Fixed-frequency generalized peak current control (gpcc) for inverters.” IEEE, 3 [10] K. S. Prakash and M. Barai, “Time-variant slope compensation for peak current mode control (pcmc) of boost converter with point-of-load applications.” IEEE, 3 2016, pp. 1–6. [11] S. Amir, R. van der Zee, and B. Nauta, “An improved modeling and analysis technique for peak current-mode control based boost converters,” IEEE Transactions on Power Electronics, vol. 30, pp. 5309–5317, 9 2015. [12] M. S. Manoharan, A. Ahmed, and J.-H. Park, “Digital implementation of peak current mode control for single-phase [13] F. Tian, S. Kasemsan, and I. Batarseh, “An adaptive slope compensation for the single-stage inverter with peak currentmode control,” IEEE Transactions on Power Electronics, vol. 26, pp. 2857–2862, 10 2011. [14] S. Veréb, A. Futó, Z. Süttö, A. Balogh, and I. Varjasi, “Continuous cross-period single phase shift control for dual active bridge converters,” Renewable Energy and Power Quality Journal, vol. 19, pp. 222–228, 9 2021. |
||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
|
||||||||||||