Abstract In this paper, an LCL filter for a 20-kW SiC powerinverter with a 25 kHz switching frequency is proposed and assessed. The transfer function without neglecting the network effect is considered. The optimal value of the damping resistor is evaluated to minimize losses while maintaining power quality and device stability. Finally, the harmonic content produced by the SiC inverter is experimentally measured to verify the effectiveness of the LCL filter. Key words: LCL filter, SiC inverter, harmonic contents, transfer function.
References [1] X. Zhang, “Passive component weight reduction for three phase power converters”, Doctoral thesis, Faculty of the Virginia Polytechnic Institute and State University Blacksburg, Virginia (2014), [Online], Available: https://vtechworks.lib.vt.edu/handle/10919/47788. [2] Y. Liu, “Filter design of high power density converter with weight, size and thermal considerations”, Doctoral thesis, Nanyang Technological University, Singapore (2018). [Online], Available: https://doi.org/10.32657/10356/74087. [3] IEC 61000-2-2:2002, “Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems”, Edition 2.0, 2002. [4] S. Takahashi, S. Ogasawara, M. Takemoto, K. Orikawa and M. Tamate, “Experimental Evaluation of the Relationship between Filter Inductor Impedances and Dimensional Resonances of MnZn Ferrites”, 2019 IEEE 4th International Future Energy Electronics Conference (IFEEC), Singapore (2019), pp. 1-8, doi: 10.1109/IFEEC47410.2019.9015169. [5] Y. Liu, K.Y. See, S. Yin, R. Simanjorang, C. F. Tong, A. Nawawi and J.-S. J. Lai, “LCL Filter Design of a 50-kW 60-kHz SiC Inverter with Size and Thermal Considerations for Aerospace Applications”, IEEE Transactions on Industrial Electronics (2017). Vol. 64, No.10, pp. 8321-8333. doi: 10.1109/TIE.2017.2677338. [6] R. Peña-Alzola, M. Liserre, F. Blaabjerg, R. Sebastián, J. Dannehl and F. W. Fuchs, “Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters”, IEEE Transactions on Power Electronics (2013), Vol. 28, No. 6, pp. 2642–2646. doi: 10.1109/TPEL.2012.2222931. [7] A. Reznik, M. G. Simões, A. Al-Durra and S. M. Muyeen, “LCL Filter Design and Performance Analysis for Grid-Interconnected Systems”, IEEE Transactions on Industry Applications (2014), Vol. 50, no. 2, pp. 1225-1232. doi: 10.1109/TIA.2013.2274612. [8] Mohamed Azab, “Multi-objective design approach of passive filters for single-phase distributed energy grid integration systems using particle swarm optimization”, Energy Reports (2020), Vol. 6, pp. 157-172, https://doi.org/10.1016/j.egyr.2019.12.015. [9] P. Channegowda and V. John, “Filter Optimization for Grid Interactive Voltage Source Inverters”, IEEE Transactions on Industrial Electronics (2010), Vol. 57, no. 12, pp. 4106-4114, Dec. 2010, doi: 10.1109/TIE.2010.2042421. [10] S. Martín-Arroyo, J. A. Cebollero, M. García-Gracia and Á. Llamazares, “Stand-Alone Hybrid Power Plant Based on SiC Solar PV and Wind Inverters with Smart Spinning Reserve Management”, Electronics (2021), Vol. 10, No. 796. https://doi.org/10.3390/electronics10070796. [11] V. Blasko and V. Kaura, “A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter”, IEEE Transactions on Industry Applications (1997), Vol. 33, No. 2, pp. 542–550. doi: 10.1109/28.568021 |
||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
|
||||||||||||